A Simplified Method for Assessing Thermal Stresses During the Construction of Massive Monolithic Foundation Slabs Based on Temperatures at Three Points

For massive monolithic foundation slabs, the risk of early cracking during construction is a pressing issue. This problem is primarily caused by thermal stresses arising from uneven heating of the structure during concrete curing and cooling. The most common approach to assessing thermal stresses is...

Cur síos iomlán

Sábháilte in:
Sonraí bibleagrafaíochta
Príomhchruthaitheoirí: Vasilina Tyurina, Anton Chepurnenko, Denis Tkachev
Formáid: Artigo
Teanga:Inglês
Foilsithe / Cruthaithe: MDPI AG 2026-01-01
Sraith:Buildings
Ábhair:
Rochtain ar líne:https://www.mdpi.com/2075-5309/16/1/188