Performance of stirrup-confined concrete-filled steel tubular stub columns under axial loading: A further investigation

To investigate the effects of stirrup ratio and connection type of stirrups on axial compression performance of stirrup-confined concrete-filled steel tubular (CFST) stub column, experiments were conducted on 16 CFST stub columns. The axial compressive bearing capacity and ductility of square and ci...