Codi QR

Study on sealing performance of main gate valve of marine nuclear power plant based on fluid-solid-thermal coupling method

IntroductionThe main gate valve is a critical component of the coolant system in marine nuclear power plants, yet its integrity is often compromised by leakage, particularly during transient operations. This study employs a fluid-solid-thermal coupling method to numerically investigate the sealing p...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Chen Yuqing, Yu Hang, Fu Shengwei, Li Ang
Format: Artigo
Idioma:Inglês
Publicat: Frontiers Media S.A. 2024-11-01
Col·lecció:Frontiers in Energy Research
Matèries:
Accés en línia:https://www.frontiersin.org/articles/10.3389/fenrg.2024.1375806/full