Código QR (código de barras bidimensional)

Pacemaker - Mediated tachycardia leading to ventricular tachycardia and syncope

An 84-year-old patient with St Jude Medical Endurity TM 2140 DDDR PPM presented with episodes of palpitations and syncope of 1-month duration. In the hospital, he was detected to have PMT. The tachycardia was initiated by a prolonged AV delay due to active VIP TM algorithm. The pacemaker EGMs at the...