Código QR (código de barras bidimensional)

What is the best procedure for determining removal rate coefficients in horizontal flow treatment wetlands: influent and effluent concentrations or longitudinal concentration profiles?

First-order removal rate coefficients (k) are used in predictive equations for estimating effluent concentrations from horizontal flow (HF) wetlands. Due to limited resources, influent and effluent concentration data from existing systems are frequently used in the estimation of k values from operat...

ver descrição completa

Na minha lista:
Detalhes bibliográficos
Principais autores: Marcos von Sperling, Scott D. Wallace, Jaime Nivala
Formato: Artigo
Idioma:Inglês
Publicado em: IWA Publishing 2023-05-01
coleção:Water Science and Technology
Assuntos:
Acesso em linha:http://wst.iwaponline.com/content/87/10/2541