COMPARISON OF BITE FORCE RECOVERY FOLLOWING TREATMENT OF MANDIBULAR ANGLE FRACTURE USING ONE AND TWO MINIPLATES
INTRODUCTION: Rigid internal fixation using compression and non-compression plating systems has gained widespread popularity. The maximal bite force is the effort exerted between the maxillary and mandibular teeth when the mandible is elevated by the masticatory muscles. OBJECTIVES: The Present stud...
Guardat en:
| Autors principals: | , , , |
|---|---|
| Format: | Artigo |
| Idioma: | Inglês |
| Publicat: |
Alexandria University, Faculty of Dentistry
2017-12-01
|
| Col·lecció: | Alexandria Dental Journal |
| Matèries: | |
| Accés en línia: | https://adjalexu.journals.ekb.eg/article_57918_68a3cd2afc63e24064f33e75561ae3ae.pdf |
| Etiquetes: |
Sense etiquetes, Sigues el primer a etiquetar aquest registre!
|