Codice QR

Comparison between thermodilution and Fick methods for resting and exercise‐induced cardiac output measurement in patients with chronic dyspnea

Abstract Studies comparing thermodilution (TD) and the direct Fick method (dFM) for cardiac output (CO) measurement are rare. We compared CO measurements between TD (2–5 cold water injections), the dFM, and indirect Fick method (iFM) at rest and during exercise, and assessed the effect of averaging...

Descrizione completa

Salvato in:
Dettagli Bibliografici
Autori principali: Susanna Desole, Anne Obst, Dirk Habedank, Christian F. Opitz, Christine Knaack, Franziska Hortien, Alexander Heine, Beate Stubbe, Ralf Ewert
Natura: Artigo
Lingua:Inglês
Pubblicazione: Wiley 2022-07-01
Serie:Pulmonary Circulation
Soggetti:
Accesso online:https://doi.org/10.1002/pul2.12128