Relationship between axillary nerve and percutaneously inserted proximal humeral locking plate: a cadaver study

Abstract Objective: The aim of this study was to investigate the relationship between the axillary nerve and the percutaneously inserted proximal humeral locking plate and to evaluate the risk of axillary nerve injury during percutaneous plate insertion. Methods: The study included 50 shoulders...