Estimation of Dose Perturbation Due to the Presence of Metal Hip Prostheses in Radiotherapy with Electron and Photon Beams: A Monte Carlo Study

Purpose: The impact of various hip prosthesis materials on the amount of dose perturbation generated by 9 MeV electron and 18 MV photon beams during pelvic radiation therapy is analyzed in this research. Materials and Methods: The Varian 2100 C/D LINAC head for the electron (9 MeV) and photon (1...

Fuld beskrivelse

Na minha lista:
Bibliografiske detaljer
Principais autores: Morteza Hashemizadeh, Mansour Zabihzadeh, Omid Azadbakht, Masoud Jamali
Format: Artigo
Sprog:Inglês
Udgivet: Tehran University of Medical Sciences 2024-07-01
Serier:Frontiers in Biomedical Technologies
Fag:
Online adgang:https://fbt.tums.ac.ir/index.php/fbt/article/view/872