Percutaneous closure of patent ductus arteriosus with the Nit-Occlud® patent ductus arteriosus device in 268 consecutive cases
Background: The pfm Nit-Occlud® patent ductus arteriosus (PDA) device is well established for interventional closure of PDA. However, there are still limited data concerning its efficacy and follow-up in larger patient groups. Aims: This study aimed to evaluate the safety and efficacy of the Nit-Occ...
Gardado en:
| Principais autores: | , , , , , , |
|---|---|
| Formato: | Artigo |
| Idioma: | Inglês |
| Publicado: |
Wolters Kluwer Medknow Publications
2019-01-01
|
| Series: | Annals of Pediatric Cardiology |
| Assuntos: | |
| Acceso en liña: | http://www.annalspc.com/article.asp?issn=0974-2069;year=2019;volume=12;issue=3;spage=206;epage=211;aulast=Maksymenko |