Codi QR

Optical Coherence Tomography of a Folded Amniotic Membrane over a Macular Hole

<p>Introduction: Placental-derived amniotic membranes (AM) can be used for both macular holes (MHs) and corneal defects. Here, we present a short report of a recurrent full thickness MH treated with a folded AM graft. Case Presentation: Best corrected visual acuity improved from 35 letter...

Descripció completa

Guardat en:
Dades bibliogràfiques
Autors principals: Lucas Sejournet, Thibaud Mathis, Victor Vermot-Desroches, Rita Serra, Laurent Kodjikian
Format: Artigo
Idioma:Inglês
Publicat: Karger Publishers 2025-05-01
Col·lecció:Case Reports in Ophthalmology
Accés en línia:https://karger.com/article/doi/10.1159/000546057
Etiquetes: Afegir etiqueta