Chargement en cours...

P-N Junction-Based Si Biochips with Ring Electrodes for Novel Biosensing Applications

In this work, we report on the impedance of p-n junction-based Si biochips with gold ring top electrodes and unstructured platinum bottom electrodes which allows for counting target biomaterial in a liquid-filled ring top electrode region. The systematic experiments on p-n junction-based Si biochips...

Description complète

Enregistré dans:
Détails bibliographiques
Publié dans:Biosensors (Basel)
Auteurs principaux: Kiani, Mahdi, Du, Nan, Vogel, Manja, Raff, Johannes, Hübner, Uwe, Skorupa, Ilona, Bürger, Danilo, Schulz, Stefan E., Schmidt, Oliver G., Schmidt, Heidemarie
Format: Artigo
Langue:Inglês
Publié: MDPI 2019
Sujets:
Accès en ligne:https://ncbi.nlm.nih.gov/pmc/articles/PMC6956254/
https://ncbi.nlm.nih.gov/pubmed/31614428
https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3390/bios9040120
Tags: Ajouter un tag