Intraocular and extraocular hemorrhage associated with ligature release of non-valved glaucoma drainage implant

PURPOSE: To report a rare complication of non-valved glaucoma drainage device surgery. OBSERVATIONS: An 85-year-old pseudophakic white male presented with painless vision loss and bloody tears. He was 5 weeks removed from uncomplicated non-valved glaucoma drainage device (Baerveldt 101-350, [AMO, Sa...