Loading...
Intraocular and extraocular hemorrhage associated with ligature release of non-valved glaucoma drainage implant
PURPOSE: To report a rare complication of non-valved glaucoma drainage device surgery. OBSERVATIONS: An 85-year-old pseudophakic white male presented with painless vision loss and bloody tears. He was 5 weeks removed from uncomplicated non-valved glaucoma drainage device (Baerveldt 101-350, [AMO, Sa...
Saved in:
Published in: | Am J Ophthalmol Case Rep |
---|---|
Main Authors: | , , |
Format: | Artigo |
Language: | Inglês |
Published: |
Elsevier
2017
|
Subjects: | |
Online Access: | https://ncbi.nlm.nih.gov/pmc/articles/PMC5758030/ https://ncbi.nlm.nih.gov/pubmed/29503962 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.1016/j.ajoc.2016.11.010 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|