Loss of signal in recurrent nerve neuromonitoring: causes and management

During recurrent laryngeal nerve (RLN) neuromonitoring in thyroid surgery, laryngeal electromyography (EMG) amplitude may be correlated with the number of muscle fibers participating in the polarization and these might be correlated with the function of RLN. If RLN is severely injured during the ope...