Bisphosphonate-coated external fixation pins appear similar to hydroxyapatite-coated pins in the tibial metaphysis and to uncoated pins in the shaft: A randomized trial
BACKGROUND AND PURPOSE: External fixation pins tend to loosen with time, especially from cancellous bone. A coating that releases a bisphosphonate has been shown to improve the fixation of dental implants in humans. We now tested a bisphosphonate coating on steel pins for external fixation. The prim...
Wedi'i Gadw mewn:
Prif Awduron: | , |
---|---|
Fformat: | Artigo |
Iaith: | Inglês |
Cyhoeddwyd: |
Informa Healthcare
2013
|
Pynciau: | |
Mynediad Ar-lein: | https://ncbi.nlm.nih.gov/pmc/articles/PMC3715817/ https://ncbi.nlm.nih.gov/pubmed/23621808 https://ncbi.nlm.nih.govhttp://dx.doi.org/10.3109/17453674.2013.797315 |
Tagiau: |
Ychwanegu Tag
Dim Tagiau, Byddwch y cyntaf i dagio'r cofnod hwn!
|