Early-phase technetium-99m sestamibi scintigraphy can improve preoperative localization in primary hyperparathyroidism

BACKGROUND: In hyperparathyroidism, dual-phase technetium-99m sestamibi scintigraphy is important for parathyroid adenoma localization. We hypothesized that reviewing early-phase scans can increase localization in patients with primary hyperparathyroidism (PHPT). METHODS: We reviewed our prospective...

Descripción completa

Guardado en:
Detalles Bibliográficos
Autores principales: Burke, Jocelyn F., Naraharisetty, Kalpana, Schneider, David F., Sippel, Rebecca S., Chen, Herbert
Formato: Artigo