Catastrophic osteomyelitis following percutaneous wire fixation of a distal radial fracture: a cautionary tale of poor patient selection followed by surgical mishap
We present a case of distal radius fracture. Several sequential unfortunate events resulted in a poor outcome. The patient was poorly selected because the degree of early dementia was not fully appreciated, due to intermittent periods of lucidity. Having elected to treat this distal radius fracture...