Absolute Copy Number and Relative Change in Determinations of Human Immunodeficiency Virus Type 1 RNA in Plasma: Effect of an External Standard on Kit Comparisons
Use of a common set of human immunodeficiency virus type 1 (HIV-1) RNA standards eliminated differences among absolute HIV-1 RNA copy number estimates made with three commercially available assays. The relative changes in the viral RNA levels determined by the commercial assays were similar and were...